EHR-Integrated High-Sensitivity Troponin Pathway Improves ED Efficiency For Patients With Chest Pain

An electronic health record (EHR)-integrated high-sensitivity cardiac troponin (hs-cTn) pathway demonstrated significant reductions in emergency department (ED) length of stay and reduced time from evaluation to disposition and time to serial assay results in patients with serial troponin measurements, according to results from a retrospective quality improvement study published in JAMA Network Open.

Leon Z. Jia, MD, et al., included 16,094 patient encounters (57% female, mean age 50 years) from four urban EDs in one health system – 7,608 patients were part of the preimplementation conventional cTn assay group from June 1, 2021, to March 31, 2022, while 8,486 made up the postimplementation integrated hs-cTn pathway group from June 1, 2022, to March 31, 2023.

The study's primary outcome was ED length of stay. The authors found that the EHR-integrated hs-cTn pathway was associated with a significant decrease in mean ED length of stay from 6.18 (95% CI, 6.10-6.26) hours to 5.64 (95% CI, 5.57-5.71) hours.

There was also an association between pathway implementation and shorter time from evaluation to disposition in patients receiving serial troponin measurements (5.06 [95% CI, 4.97-5.15] hours vs. 6.68 [95% CI, 6.52-6.85] hours; p<0.001). Time from first troponin order to second troponin result also decreased in the pathway implementation group for both admitted and discharged patients.

"Our findings suggest that the operational efficiency gains associated with hs-cTn adoption may depend heavily on workflow integration," the authors write. "Previous studies have found mixed associations of hs-cTn implementation with ED efficiency, with some showing decreased [length of stay] and other identifying increased testing burden as a barrier to improvement in time-based measures."

In an accompanying editorial comment, James S. Ford, MAS; William B. Stubblefield, MD, MPH; and Jesse O. Wrenn, MD, PhD, add: "As hs-cTn assays are increasingly embedded in contemporary emergency cardiovascular care workflows, the central question is no longer whether these assays should be used but how they can be implemented most effectively and how they affect downstream care and patient outcomes. The findings of Jia et al. suggest that thoughtfully designed, EHR-integrated pathways may generate meaningful gains in ED efficiency while also highlighting the tradeoffs intrinsic to more sensitive diagnostic testing."

Resources

Keywords: Diagnostic Techniques and Procedures, Electronic Health Records, Emergency Service, Hospital, Length of Stay, Chest Pain, Troponin, Quality Improvement, Workflow